For the complete documentation index, see llms.txt. Markdown versions of documentation pages are available by appending .md to page URLs.
Skip to content

MS SQL Server

MS SQL Server CDC source. Reads row-level changes from SQL Server CDC change tables; covers enabling CDC per table, permissions, and sink configuration.

MS SQL Server is supported as a CDC source for capturing inserts, updates, and deletes at row granularity. Nilus's CDC engine reads the CDC change tables that SQL Server maintains for each enabled source table. Nilus persists offsets through its REST-backed offset store and persists DDL through the REST schema-history store, so a restart resumes from the last acknowledged position with the correct schema context.

Nilus connects to MS SQL Server through a DataOS depot resolved with pipeline type: cdc. The depot keeps host, port, credentials, and driver settings outside the pipeline manifest.

Connectivity

Form
Address example
Notes

DataOS depot

dataos://mymssqldepot?purpose=ro

Host, port, credentials, and TLS material are resolved from the depot definition.

Defaults applied by Nilus:

  • topic.prefix = cdc (override per pipeline; the prefix is also used as the sink table prefix)

  • database.encrypt = false by default; pass additional database.* properties through source.cdc if your environment requires TLS or instance-specific settings.

  • Each change event is emitted with the new row state and timestamp metadata; deletes preserve the original primary key.

  • DDL is persisted through the REST schema-history store.

Requirements

These requirements must be satisfied at the database before Nilus can run a SQL Server CDC pipeline.

Enable CDC at the database and table level

USE MyDB;
GO
EXEC sys.sp_cdc_enable_db;
GO

EXEC sys.sp_cdc_enable_table
  @source_schema       = N'dbo',
  @source_name         = N'customers',
  @role_name           = NULL,    -- optional gating role
  @supports_net_changes = 0;
GO

Repeat sp_cdc_enable_table for every table Nilus is expected to capture. The role passed via @role_name (or NULL for none) controls which database principals can read the underlying CDC change tables; if you set a role, the Nilus runtime user must be a member.

SQL Server Agent must be running

SQL Server Agent populates and trims the CDC change tables. If the Agent stops, no new change rows are produced and the pipeline silently goes idle even though source writes continue.

Privileges

  • The operator who enables CDC needs elevated privileges such as sysadmin and db_owner.

  • The Nilus runtime user needs:

    • db_datareader (or column-scoped SELECT) on the captured columns.

    • Membership in the gating role configured by @role_name, if any.

    • VIEW SERVER STATE if you rely on the engine's default Agent status check; otherwise supply a custom status query through source.cdc.

CDC retention

CDC change tables are pruned by the Agent's clean-up job. Retention must be long enough to cover any planned downtime, if cleanup removes change rows that Nilus still needs, a fresh snapshot is required. Default retention is three days; for production CDC pipelines, raise it explicitly.

Schema and feature constraints

  • Indexed views are not supported.

  • Schema changes on captured tables require creating a new CDC capture instance; the connector transitions to it once both instances exist briefly in parallel.

  • Tables without a primary key cannot stream updates and deletes reliably.

Sample Nilus config

The depot referenced as dataos://mymssqldepot?purpose=ro resolves connection details (host, port, credentials, TLS) from its DataOS definition; no inline secret projection is needed in the manifest above.

CDC options

These are the most useful CDC connector properties for SQL Server. They go under source.cdc in the Nilus manifest.

Option
Default
Description

database.names

No default

Comma-separated list of databases to capture. SQL Server CDC connector reads from all listed databases on the same server.

table.include.list

No default

Comma-separated list of fully qualified schema.table identifiers to capture.

table.exclude.list

No default

Inverse of table.include.list.

column.include.list

No default

schema.table.column patterns to include in change events.

column.exclude.list

No default

Inverse of column.include.list.

topic.prefix

cdc (Nilus default)

Logical namespace for this pipeline. Must be unique across CDC pipelines. Nilus also uses it as the sink table prefix.

snapshot.mode

initial

Snapshot behavior on first start. initial snapshots when no offset is recorded; always re-snapshots every start; schema_only captures only schema (skip data); when_needed snapshots when the recorded offset is no longer available.

database.encrypt

false (Nilus default)

Set to true and provide trust settings if the SQL Server instance enforces TLS.

database.trustServerCertificate

Driver default

Useful in dev environments where the server certificate is self-signed.

heartbeat.interval.ms

0 (off)

Periodic heartbeats keep the persisted offset advancing on idle databases. Recommended: 60000.

max.batch.size

2048

Maximum number of change events processed per batch.

max.queue.size

8192

Maximum buffered change events before back-pressure kicks in.

offset.flush.interval.ms

60000

How often offsets are persisted to the Nilus REST offset store.

strategy

flatten

flatten emits row-shaped records (one row per change). changelog preserves the full CDC envelope. Set under source.options, not source.cdc.

Core concepts

  1. Change tables, not log mining

    • SQL Server materializes committed row changes into CDC change tables under the cdc schema.

    • Nilus reads from those change tables rather than tailing the transaction log directly.

    • The Agent process is responsible for keeping change tables current, so its health is part of the CDC contract.

  2. Snapshot + stream flow

    • Nilus begins with a consistent snapshot of the captured tables and then continues from CDC change rows as new transactions commit.

    • Snapshot mode is configurable through snapshot.mode.

    • On restart, the persisted offset is reused so the snapshot phase is skipped.

  3. Offset and schema-history persistence

    • Offsets are persisted to the Nilus REST offset store; restart points to the last acknowledged change-table position.

    • DDL is persisted to the REST schema-history store, so the connector can rebuild table schemas without reading from the source.

  4. Capture instances and schema evolution

    • Each captured source table maps to a CDC capture instance. Compatible schema changes (additive columns) flow through naturally.

    • Incompatible changes, column renames, type changes, primary-key changes, require a new capture instance and a deliberate cut-over.

  5. Operational risk areas

    • Agent health, CDC retention, and capture-instance management dominate operating effort.

    • Network partitions cause the connector to retry; long partitions can push the persisted offset behind retention and force a fresh snapshot.

Behavior and capabilities

  • Pipeline type: MS SQL Server CDC runs as a cdc source.

  • Keep SQL Server Agent healthy and monitored. If it stops, Nilus stops receiving new CDC rows even though source writes continue.

  • Use a narrow table.include.list instead of capturing every CDC-enabled table by default.

  • Keep topic.prefix stable after the first production deployment because downstream naming depends on it.

  • For incompatible schema changes, create a new capture instance and cut the pipeline over deliberately rather than expecting the existing one to adapt automatically.

  • Raise CDC retention before turning on the pipeline. Three days (the default) is rarely enough for production.

Troubleshooting

  • Symptom: No new events arrive even though source tables are changing.

    • Cause: SQL Server Agent is stopped, CDC is not enabled on the table, or the table is missing from table.include.list.

    • Recovery: Verify Agent status, confirm sys.sp_cdc_help_change_data_capture returns the table, and redeploy with the correct include list.

  • Symptom: Pipeline fails after a long pause.

    • Cause: CDC cleanup removed change rows that Nilus still needed.

    • Recovery: Increase CDC retention, validate the cleanup job settings, and restart the pipeline with a fresh snapshot.

  • Symptom: Downstream columns stop matching the source after a schema change.

    • Cause: The source table moved to a new capture instance, or the old capture instance no longer reflects the source schema.

    • Recovery: Create and validate the new capture instance, then redeploy the Nilus pipeline so it transitions cleanly.

  • Symptom: Connector errors out reading Agent status.

    • Cause: The runtime user lacks VIEW SERVER STATE and the engine's default status query is blocked.

    • Recovery: Grant VIEW SERVER STATE, or supply a custom status query through source.cdc.snapshot.select.statement.overrides.

Last updated