MongoDB CDC error 286
Error 286 indicates that a MongoDB change stream (which Nilus relies on for CDC) attempted to resume from a point that is no longer present in the replica‑set oplog (local.oplog.rs). When this...
This page explains MongoDB CDC error 286, its root cause (oplog history loss), and how to prevent and recover from it.
Error 286 is a symptom of history loss: the resume token is gone.
The root cause is an undersized or force-truncated oplog relative to the maximum connector lag.
Prevention: correct oplog sizing, sufficient connector throughput, and monitoring.
Recovery is straightforward (new snapshot or larger oplog) but can be time-consuming. Plan ahead.
Error 286 indicates that a MongoDB change stream (which Nilus relies on for change data capture) attempted to resume from a point that is no longer present in the replica-set oplog (local.oplog.rs). When this happens, Nilus logs the following exception:
Command failed with error 286 (ChangeStreamHistoryLost):
Resume of change stream was not possible, as the resume point may no longer be in the oplogUnderstanding why the oplog entry disappeared and how to size and monitor the oplog is critical for reliable CDC.
The MongoDB oplog in a nutshell
A capped collection (
local.oplog.rs) that stores every write against the primary so secondaries (and tools such as Nilus) can replicate those changes.The oplog is truncated on a first-in-first-out basis once it reaches its allocated size.
Default size: when you initiate a replica set, MongoDB chooses the oplog size automatically: 5% of free disk space (minimum about 990 MB).
Because the collection is capped, what matters is the time window: how many hours of history does this size translate to under your peak write load?
Why error 286 happens
The connector is paused or slowed down; older entries roll off before it resumes.
Manually shrinking the oplog or re-initializing the replica set discards old tokens.
MongoDB may truncate more aggressively if the filesystem is full.
Very high write bursts, such as a bulk load, shrink the effective time window.
When the connector restarts it looks up its resume token in the oplog. If that token has vanished, MongoDB throws error 286 and Nilus refuses to start.
Recovery options
Delete and reapply the failing service with a new PV directory or PVC. Alternatively, keep the connector running and delete the offset (from the PVC directory) so Nilus treats it as new and snapshots again.
OR
Change the name of the connector service (from
nilus:0.0.13onwards) using the same config. Nilus takes a snapshot (as specified bysnapshot.mode) and then continues to stream changes.
Note: Error 286 cannot be resolved by simply restarting the connector. Manual intervention is required to restore the service once this error occurs.
Preventing error 286
Size the oplog for worst-case lag
MongoDB 4.4+ also supports
replSetResizeOplog, and 6.0 addsminRetentionHoursfor time-based guarantees.
The objective is to make sure the oplog retains at least as much history as the connector could ever fall behind, with headroom for bursts. Formula: RequiredSize(MB) ≈ PeakWrites/sec × MaxLag(sec) × avgEntrySize × safetyFactor
Peak writes/sec: Insert + Update + Delete ops during the busiest interval (consult
serverStatus().opcountersor monitoring).Max lag: Longest plausible outage or back-pressure window (connector maintenance + downstream outage + buffer).
avgEntrySize: In bytes; rule of thumb about 1 kB if most documents are small.
safetyFactor: 1.3 to 2.0 depending on risk appetite.
Monitor key metrics
Use
rs.printReplicationInfo()to retrieve information on the oplog status, including the size of the oplog and the time range of operations.
Avoid long pauses
Schedule connector downtime within the calculated oplog window.
Recommended Nilus source options
snapshot.mode
Controls what Nilus does when offsets are missing.
• Set to initial (default) or always if you anticipate long downtimes
• when_needed • After the connector starts, it performs a snapshot only if either It cannot detect any topic offsets or a previously recorded offset specifies a log position that is not available on the server
offset.flush.interval.ms
How often offsets are committed. Shorter intervals reduce duplicate events after crashes.
15000 ms
heartbeat.interval.ms
Emits heartbeat records to keep offsets moving even when no data changes. Helps detect lag early.
5000–10000 ms
max.batch.size, max.queue.size & max.queue.size.in.bytes
Tune to keep connector processing speed > peak write rate, avoiding backlog.
Start with small (eg. 250 / 2000 & 128 MB), adjust according to the data volume and change frequency
Operational playbook
Daily
- Monitor oplog window & connector lag
- Alert if lag > 80 % of window
Before maintenance
- Calculate expected pause; if > window, increase oplog temporarily
After unplanned outage
- If connector fails with 286, decide between re‑snapshot or clean the PV directory
After success
- Review sizing assumptions; adjust oplogSizeMB or Nilus throughput limits